2D-4. Flow Test - Refer to Figure 3.
1. Install Tube Adapter on injector. Use Teflon thread tape as
needed.
2. Connect the end of the Ozone Tube with the check valve
installed onto the Tube Adapter with the tube clamp provided.
3. Connect the longer end of the Flow Meter Assembly to the
Ozone Outlet Barb.
4. Connect the remaining ends of the Ozone Tube and the Flow
Meter Assembly together.
5. Hold the Flow Meter Assembly so that the clear plastic chamber
is vertical with the longer tubing toward the bottom.
6. Turn on the pool’s circulation system as this allows the Injector
Assembly to pull a vacuum. Under normal operation, the metal
ball in the Flow Meter Assembly will be floating in between its
Max and Min line. Under worst-case system conditions the
flowmeter ball should indicate at least a small amount of air flow.
Flow may be adjusted as described below.
Adjustable Injector Manifold: Gas flow can be controlled by
adjusting the Valve on the Manifold. Close the valve to increase gas
flow, open the Valve to decrease gas flow.
Rigid Injector Manifold: This Manifold is equipped with a
DELCheck
TM
spring loaded valve. It cannot be adjusted, but